Highway Guardrail Pile Driver

Classification: Highway Guardrail Pile Driver


Brand Name: FORST


Brief Introduction:

Highway Guardrail Pile Driver(Pile driver、Pile puller、driller) Parameter NameUnitParameterParameter NameUnitParameterEngine rated powerKwA 33KW,A 51KWEngine BrandAChina FAW XichaiA Weichai EngineMachine Size(In Working)mm3250×2000×3400...


Product Details

Highway Guardrail Pile DriverPile driverPile pullerdriller


Highway Guardrail Pile Driver



Parameter Name


Unit


Parameter


Parameter Name


Unit


Parameter


Engine rated power

Kw

A 33KW,A 51KW
 
 


Engine Brand



A China FAW Xichai
A Weichai Engine


Machine Size

In Working)

mm

3250×2000×3400    (Column height after folding2400)


Impact Frequency of Hydraulic Hammer

/min

500-900


Piling Height

Meter

2.7


Hydraulic Hammer Working Flow

ml/r

30-50


Machine Weight

kg

3200


Hydraulic Hammer Working Pressure

Mpa

12~16


Hydraulic System Working Pressure

MPa

16


Air Flow

M3/min

8


Hydraulic System Flow

ml/r

50


Working Air Pressure

MPa

0.5-1


Drilling Diameter

mm

Ø80~ ø180


Drilling Depth

Meter

0.5-1.8


Drilling Speed

mm/min

500


Gradeability

Angle

<=25°


Driving speed

Km/n

10~15


Towing speed

KM/h

30-40


Drill rod diameter

mm

75-85


Drilling Depth

/min

1200


Hydraulic Hammer Model

kg

360





Remarks:This machine has hydraulic power steering, four-wheel hydraulic brake, collapsible column, on-board steering, high-speed drilling machine, hydraulic outrigger.

Guardrail Pile Driver maintenance


Fault 1 Oil pump does not turn: the reason does not hang up the oil pump engaging device, the elimination method steps down the clutch to hang up the oil pump engaging device

Fault 2 Multi-way valve does not return to the center: The return spring is damaged. Troubleshooting Method Replace the return spring

Fault 3 The multi-way valve is difficult to operate: The cause is that iron filings or dirt is in the valve stem. Troubleshooting Method Remove iron filings or dirt

Fault 4 Slow frequency and weak operation:

Cause 1 Nitrogen leaks and the pressure is insufficient. Use a nitrogen manometer to check and keep the nitrogen pressure at 1.2Mpa

Reason 2 Lack of hydraulic oil, elimination method to add hydraulic oil.

Cause 3 The oil suction filter is blocked. Troubleshooting Method Remove the blockage, clean it, or replace it.

Cause 4 The pump does not suck oil. The solution is to solve the leakage of the suction pipe or the drying of the suction pipe. A vacuum cannot be formed to fill the suction pipe with oil.

Cause 5 The safety valve fails or the adjustment pressure is low. Replace the spring of the safety valve or adjust the pressure to 16Mpa.

Reason 6 fence piling oil cylinder seal is poor, elimination method check or replace the sealing ring